| MODEL NO. | 12 Volt System 24 Volt System 48 Volt System | PM-1500SSL-12X(1) PM-1500SSL-24X PM-1500SSL-48X | PM-3000SSL-12X(1) PM-3000SSL-24X PM-3000SSL-48X |
| GENERAL |
| Ventilation | Forced cooling | Forced cooling |
Temperature
| Operation Storage | -20°C ~ +70°C -25°C ~ +80°C | -20°C ~ +70°C -25°C ~ +80°C |
| Protection | | |
| | a. Output short circuit | ∨ | ∨ |
| | b. Over load | ∨ | ∨ |
| | c. Battery voltage too high | ∨ | ∨ |
| | d. Battery voltage too low | ∨ | ∨ |
| | e. DC voltage ripple too high | ∨ | ∨ |
| | f. Temperature Sensor | | |
| | Transformer | ∨(105°C) | ∨(105°C) |
| | Electronic & Powerstage | ∨(70°C) | ∨(70°C) |
| | BTS-3 | ∨(50°C) | ∨(50°C) |
| Humidity | 0~95% (non condensing) | 0~95% (non condensing) |
| Power control Function | ∨ | ∨ |
| Power assist Function | ∨ | ∨ |
| Uninterrupted AC power | ∨(less than 10 msec) | ∨(less than 10 msec) |
| Adaptive 4-stage charge | ∨ | ∨ |
| Two output to charge 2 battery banks | ∨ | ∨ |
| Auxiliary Relay | X 3 | X 3 |
| Battery voltage sensor | ∨ | ∨ |
| Battery Temperature sensor (BTS-3) | ∨ | ∨ |
| Remote control port | ∨ | ∨ |
| INVERTER |
| Input Voltage Range (VDC) | 9.5~16V / 19~32V / 38~64V |
| Output Voltage (VAC) | 185~240 VAC / 90~120 VAC |
| Output Frequency | 50Hz / 60Hz ± 0.1% |
| Output Waveform | Pure sinewave |
| Output Voltage THD | < 5% |
| Power Factor (All Loads) | ∨ |
| No linger load, crest factor | 3 : 1 |
Cont. Power Output (W) Under 70°C (cosθ=1.0) | 1500W (No derate) | 3000W (No derate) |
Cont. Power Output (W) Over 70°C (cosθ=1.0) | 0W (Shutdown) | 0W (Shutdown) |
| Maximum Power (W) | 3000W | 6000W |
| Maximum Efficiency (%) | 82/84/85 | 84/86/89 |
| Zero-load Power (W) | 12W | 18W |
| CHARGER |
| Input Voltage Range (VAC) | 200~250 VAC / 100~125 VAC |
| Input Frequency | 45-55Hz / 55-65 Hz |
| Power Factor | 1 |
| Charge Characteristic | 4-stage adaptive / Bulk-Absorption-Float-Equalize |
| Maximum DC Voltage Ripple (Vrms) | < 1.25 V |
| Charge Current House Battery (A) | 70A/40A/20A | 140A/70A/40A |
| Charge Current Starter Battery (A) | 4A |
| Absorption Voltage Default (VDC) | 14.4V / 28.8V / 57.6V |
| Float voltage Default (VDC) | 13.8V / 27.6V / 55.2V |
| Equalize Voltage default (VDC) | 13.2V / 26.4V / 52.8V |
| Output Charge Voltage (min ~ max) | 8V~16V / 11V~32V / 22V~64V |
| Battery Temperature sensor | BTS-3 |
| SOLAR CHARGE |
| System voltage ratings | 12, 24, 48 Vdc |
| Current ratings-Battery Charge Control | 40A |
| Accuracy | 12/24V:≤0.1 % ± 50 mV 48V:≤0.1 % ± 100 mV |
| Min. voltage to operate | 9V |
| Max. solar array Voc | 140V |
| Max. operating voltage | 68V |
| Total current consumption | While operating -25mA, at idle -3mA |
| High temp shutdown | 90°C disconnect solar 70°C reconnect solar |
| Transient surge protection |
| | pulse power rating | 4500 watts |
| | Response | < 5 nanosec |
| ENVIRONMENTAL |
| Ambient temperature | -40 to +45°C |
| Storage temperature | -55 to +85°C |
| Humidity | 100% (NC) |
| AC INPUT SWITCH |
| AC IN Terminal Circuit Breaker | 30A (110V) /15A (220V) | 60A (110V) /30A (220V) |
| Switch-over Time | |
| | a. inverter to AC input | 0 msec. |
| | b. AC input to inverter | 0 msec. |
| Detection Time AC Input Fault | 4 ~10 msec. |
| Trip Level AC Input to Inverter | 90 VAC / 180 VAC |
| Trip Level Inverter to AC Input | 94 VAC / 187 VAC |
| Min.~ Max. Frequency Range | 45-55 Hz / 55-65 Hz |
| MECHANICAL |
| Cabinet / Protecting Class | Aluminum / IP20 |
| Dimension (H X W X D) | Wall: 298 x 256 x 368 Table: 189 x 285 x 494 (mm) | Wall: 355 x 256 x 368 Table: 189 x 285 x 708 (mm) |
| Weight (kgs) | 30 kgs | 35 kgs |